{"id":11808,"date":"2025-05-08T13:56:25","date_gmt":"2025-05-08T11:56:25","guid":{"rendered":"https:\/\/samotics.com\/?p=11808"},"modified":"2026-01-07T12:35:10","modified_gmt":"2026-01-07T11:35:10","slug":"identifying-and-fixing-a-broken-sine-wave-filter-in-electric-submersible-pumps","status":"publish","type":"post","link":"https:\/\/samotics.com\/pt\/case-studies\/identifying-and-fixing-a-broken-sine-wave-filter-in-electric-submersible-pumps","title":{"rendered":"Identifica\u00e7\u00e3o e repara\u00e7\u00e3o de um filtro sinusoidal avariado em bombas el\u00e9ctricas submers\u00edveis"},"content":{"rendered":"<h2>Harm\u00f3nicos inesperados e desequil\u00edbrio de tens\u00e3o num acionamento ESP<\/h2>\n<p>Um cliente enfrentou problemas recorrentes com uma das suas instala\u00e7\u00f5es de bombas el\u00e9ctricas submers\u00edveis (ESP). O SAM4 detectou padr\u00f5es harm\u00f3nicos irregulares e desequil\u00edbrio de tens\u00e3o na ESP - anomalias n\u00e3o observadas noutras ESPs a funcionar em condi\u00e7\u00f5es semelhantes. Especificamente:<\/p>\n<ul>\n<li><strong>Desfasamento de fase atual:<\/strong> As fases 1 e 3 apresentaram uma distor\u00e7\u00e3o harm\u00f3nica significativa, enquanto a fase 2 permaneceu relativamente limpa.<\/li>\n<li><strong>Harm\u00f3nicos invulgares:<\/strong> Mesmo os harm\u00f3nicos (por exemplo, 2X, 4X, 6X) estavam presentes - at\u00edpicos para sistemas trif\u00e1sicos equilibrados.<\/li>\n<li><strong>Desequil\u00edbrio de tens\u00e3o:<\/strong> As discrep\u00e2ncias detectadas apontavam para potenciais problemas na unidade de tra\u00e7\u00e3o - provavelmente p\u00f3s-VFD (Variable Frequency Drive).<\/li>\n<\/ul>\n<figure id=\"attachment_11810\" aria-describedby=\"caption-attachment-11810\" style=\"width: 763px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/samotics.com\/wp-content\/uploads\/2025\/05\/ESP-system-with-a-failed-sine-wave-filter-1.png\"><img fetchpriority=\"high\" decoding=\"async\" class=\"size-full wp-image-11810\" src=\"https:\/\/samotics.com\/wp-content\/uploads\/2025\/05\/ESP-system-with-a-failed-sine-wave-filter-1.png\" alt=\"\" width=\"763\" height=\"518\" title=\"\" srcset=\"https:\/\/samotics.com\/wp-content\/uploads\/2025\/05\/ESP-system-with-a-failed-sine-wave-filter-1.png 763w, https:\/\/samotics.com\/wp-content\/uploads\/2025\/05\/ESP-system-with-a-failed-sine-wave-filter-1-300x204.png 300w, https:\/\/samotics.com\/wp-content\/uploads\/2025\/05\/ESP-system-with-a-failed-sine-wave-filter-1-18x12.png 18w\" sizes=\"(max-width: 763px) 100vw, 763px\" \/><\/a><figcaption id=\"caption-attachment-11810\" class=\"wp-caption-text\">Sistema ESP com um filtro de onda sinusoidal avariado - Formas de onda de corrente e tens\u00e3o (0,1 segundos) medidas no lado MT do transformador elevador; e pormenores do teor de distor\u00e7\u00e3o harm\u00f3nica por fase (at\u00e9 \u00e0 13.a harm\u00f3nica).<\/figcaption><\/figure>\n<p>Estas anomalias comprometiam a qualidade da energia el\u00e9ctrica e arriscavam danos a longo prazo no motor ou nos componentes a jusante, mas a causa principal n\u00e3o era clara.<\/p>\n<h2>Resolu\u00e7\u00e3o de problemas em camadas para isolar a fonte de harm\u00f3nicos<\/h2>\n<p>O cliente, em estreita colabora\u00e7\u00e3o com a Samotics, iniciou uma abordagem de diagn\u00f3stico direcionada:<\/p>\n<ul>\n<li><strong>Segmenta\u00e7\u00e3o do grupo motopropulsor:<\/strong> Analisou as assinaturas el\u00e9ctricas em cada segmento chave: a sa\u00edda do VFD, a sa\u00edda do filtro de onda sinusoidal e a sa\u00edda do transformador elevador VT.<\/li>\n<li><strong>Valida\u00e7\u00e3o da hip\u00f3tese:<\/strong>\n<ul>\n<li>Verifica\u00e7\u00e3o de falhas de modula\u00e7\u00e3o do VFD, como distor\u00e7\u00e3o de tempo morto.<\/li>\n<li>Investiga\u00e7\u00e3o do filtro de onda sinusoidal para degrada\u00e7\u00e3o de componentes assim\u00e9tricos.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Compara\u00e7\u00e3o harm\u00f3nica:<\/strong> Comparou a tens\u00e3o e os harm\u00f3nicos de corrente do ESP com ESPs semelhantes. Isto confirmou que o problema estava isolado no ESP e n\u00e3o era sist\u00e9mico.<\/li>\n<\/ul>\n<p>Atrav\u00e9s da an\u00e1lise harm\u00f3nica e de dados comparativos, a equipa reduziu a falha a uma prov\u00e1vel degrada\u00e7\u00e3o dos componentes do filtro de ondas sinusoidais, que j\u00e1 n\u00e3o estavam a condicionar simetricamente a sa\u00edda do VFD.<\/p>\n<h2>Problema de filtro resolvido para evitar a perda de horas de produ\u00e7\u00e3o<\/h2>\n<p>Ao identificar o filtro de onda sinusoidal como a causa principal, o cliente substituiu o componente avariado e resolveu o problema central subjacente aos sinais de pot\u00eancia irregulares do ESP:<\/p>\n<ul>\n<li>Restabeleceu o equil\u00edbrio da tens\u00e3o e o fluxo de corrente sim\u00e9trico em todas as fases, fazendo com que o fornecimento de energia voltasse a estar dentro dos intervalos de funcionamento previstos.<\/li>\n<li>Elimina\u00e7\u00e3o das harm\u00f3nicas pares anormais, o que reduziu significativamente o risco de stress el\u00e9trico e de degrada\u00e7\u00e3o a longo prazo no motor ESP.<\/li>\n<li>Evitou o desgaste prematuro do motor restabelecendo uma sa\u00edda de pot\u00eancia limpa e consistente do VFD atrav\u00e9s do transformador elevador.<\/li>\n<\/ul>\n<figure id=\"attachment_11811\" aria-describedby=\"caption-attachment-11811\" style=\"width: 766px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/samotics.com\/wp-content\/uploads\/2025\/05\/ESP-system-with-a-healthy-sine-wave-filter.png\"><img decoding=\"async\" class=\"wp-image-11811 size-full\" src=\"https:\/\/samotics.com\/wp-content\/uploads\/2025\/05\/ESP-system-with-a-healthy-sine-wave-filter.png\" alt=\"\" width=\"766\" height=\"518\" title=\"\" srcset=\"https:\/\/samotics.com\/wp-content\/uploads\/2025\/05\/ESP-system-with-a-healthy-sine-wave-filter.png 766w, https:\/\/samotics.com\/wp-content\/uploads\/2025\/05\/ESP-system-with-a-healthy-sine-wave-filter-300x203.png 300w, https:\/\/samotics.com\/wp-content\/uploads\/2025\/05\/ESP-system-with-a-healthy-sine-wave-filter-18x12.png 18w\" sizes=\"(max-width: 766px) 100vw, 766px\" \/><\/a><figcaption id=\"caption-attachment-11811\" class=\"wp-caption-text\">Sistema ESP com um filtro de onda sinusoidal saud\u00e1vel - Formas de onda de corrente e tens\u00e3o (0,1 segundos) medidas no lado de MT do transformador elevador; e detalhes do conte\u00fado de distor\u00e7\u00e3o harm\u00f3nica por fase (at\u00e9 \u00e0 13.\u00aa harm\u00f3nica).<\/figcaption><\/figure>\n<p>Mas o impacto n\u00e3o se limitou ao n\u00edvel t\u00e9cnico.<\/p>\n<p>Esta corre\u00e7\u00e3o ajudou o cliente a evitar uma falha prematura do ESP com poss\u00edveis reclama\u00e7\u00f5es de responsabilidade. Evitar o tempo de produ\u00e7\u00e3o suspenso que frequentemente se segue a falhas inexplic\u00e1veis do ESP. Com a unidade ESP de volta \u00e0 linha mais rapidamente e a funcionar de forma mais fi\u00e1vel, evitaram as consequ\u00eancias t\u00edpicas do tempo de inatividade: perda de produ\u00e7\u00e3o, custos de repara\u00e7\u00e3o de emerg\u00eancia e objectivos de produ\u00e7\u00e3o n\u00e3o atingidos.<\/p>\n<p>Mais importante ainda, a investiga\u00e7\u00e3o conduziu a um fluxo de trabalho de diagn\u00f3stico repet\u00edvel para futuros problemas de filtros de ondas sinusoidais - permitindo \u00e0 equipa resolver falhas semelhantes em horas e n\u00e3o em dias. Isto significa menos atrasos, manuten\u00e7\u00e3o mais previs\u00edvel e um caminho mais r\u00e1pido desde a dete\u00e7\u00e3o at\u00e9 \u00e0 resolu\u00e7\u00e3o.<\/p>","protected":false},"excerpt":{"rendered":"<p>Unexpected harmonics and voltage imbalance in an ESP drive A customer faced recurring issues with one of its electric submersible pump (ESP) installations. SAM4 detected irregular harmonic patterns and voltage imbalance on the ESP- anomalies not seen on other ESPs operating under similar conditions. Specifically: Current phase mismatch: Phases 1 and 3 showed significant harmonic [&hellip;]<\/p>\n","protected":false},"author":28,"featured_media":11812,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"content-type":"","_lmt_disableupdate":"no","_lmt_disable":"","footnotes":""},"categories":[6],"tags":[],"coauthors":[69],"class_list":["post-11808","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-case-studies"],"modified_by":"Gino Gagliardi","_links":{"self":[{"href":"https:\/\/samotics.com\/pt\/wp-json\/wp\/v2\/posts\/11808","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/samotics.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/samotics.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/samotics.com\/pt\/wp-json\/wp\/v2\/users\/28"}],"replies":[{"embeddable":true,"href":"https:\/\/samotics.com\/pt\/wp-json\/wp\/v2\/comments?post=11808"}],"version-history":[{"count":5,"href":"https:\/\/samotics.com\/pt\/wp-json\/wp\/v2\/posts\/11808\/revisions"}],"predecessor-version":[{"id":11934,"href":"https:\/\/samotics.com\/pt\/wp-json\/wp\/v2\/posts\/11808\/revisions\/11934"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/samotics.com\/pt\/wp-json\/wp\/v2\/media\/11812"}],"wp:attachment":[{"href":"https:\/\/samotics.com\/pt\/wp-json\/wp\/v2\/media?parent=11808"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/samotics.com\/pt\/wp-json\/wp\/v2\/categories?post=11808"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/samotics.com\/pt\/wp-json\/wp\/v2\/tags?post=11808"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/samotics.com\/pt\/wp-json\/wp\/v2\/coauthors?post=11808"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}