{"id":9663,"date":"2024-09-12T14:22:57","date_gmt":"2024-09-12T12:22:57","guid":{"rendered":"https:\/\/samotics.com\/?p=9663"},"modified":"2026-01-07T13:11:36","modified_gmt":"2026-01-07T12:11:36","slug":"how-vitens-increased-operational-efficiency-by-7-through-real-time-asset-measurements","status":"publish","type":"post","link":"https:\/\/samotics.com\/es\/case-studies\/how-vitens-increased-operational-efficiency-by-7-through-real-time-asset-measurements","title":{"rendered":"C\u00f3mo Vitens aument\u00f3 su eficiencia operativa en 7% gracias a la medici\u00f3n de activos en tiempo real"},"content":{"rendered":"<h2>La ambiciosa estrategia de Vitens para mejorar la sostenibilidad con eficiencia industrial<\/h2>\n<p>\"Cada gota es sostenible\" es el lema de Vitens, la mayor empresa de agua potable de los Pa\u00edses Bajos. La empresa suministra agua potable de alta calidad a 5,6 millones de personas y empresas de 7 de las 12 provincias neerlandesas. Vitens entiende que el agua potable fiable es una necesidad para nuestra salud y bienestar, y que garantizar el suministro de este recurso esencial tiene que ser sostenible y rentable. Como empresa que sit\u00faa la responsabilidad global en el centro de su visi\u00f3n a largo plazo, Vitens se compromete a crear un ecosistema h\u00eddrico sostenible para 2030.<\/p>\n<figure id=\"attachment_9758\" aria-describedby=\"caption-attachment-9758\" style=\"width: 1920px\" class=\"wp-caption aligncenter\"><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-9758 size-full\" src=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/spannenburg-Vitens-Water.webp\" alt=\"\" width=\"1920\" height=\"1080\" title=\"\" srcset=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/spannenburg-Vitens-Water.webp 1920w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/spannenburg-Vitens-Water-300x169.webp 300w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/spannenburg-Vitens-Water-1024x576.webp 1024w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/spannenburg-Vitens-Water-768x432.webp 768w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/spannenburg-Vitens-Water-1536x864.webp 1536w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/spannenburg-Vitens-Water-18x10.webp 18w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><figcaption id=\"caption-attachment-9758\" class=\"wp-caption-text\">En Spannenburg, Vitens Water depura 25.000 millones de litros de agua potable al a\u00f1o.<\/figcaption><\/figure>\n<p>Para ello, Vitens invierte en soluciones innovadoras, utilizando los datos de forma inteligente para mejorar su rendimiento operativo. Mediante la medici\u00f3n continua (en tiempo real) y el uso de algoritmos, c\u00e1lculos de modelos y an\u00e1lisis de escenarios, se puede producir y suministrar una cantidad y calidad de agua potable m\u00e1s constante y fiable. Esto sit\u00faa a Vitens a la vanguardia de la innovaci\u00f3n en la industria del agua para mejorar la eficiencia y la sostenibilidad. La reducci\u00f3n del consumo de energ\u00eda y de las emisiones desempe\u00f1a un papel clave en este camino para Vitens, especialmente a la luz de los problemas del cambio clim\u00e1tico, la volatilidad del mercado energ\u00e9tico y el aumento de los precios de la energ\u00eda. Las bombas son el alma de las operaciones diarias de Vitens, ya que la mayor parte del consumo el\u00e9ctrico se utiliza en la extracci\u00f3n de aguas subterr\u00e1neas y la distribuci\u00f3n de agua limpia. Por lo tanto, la mejora del rendimiento y la eficiencia de las bombas tendr\u00e1 un impacto positivo en las operaciones de Vitens al reducir el consumo de energ\u00eda, los costes y el impacto medioambiental.<\/p>\n<p>&nbsp;<\/p>\n<p>Vitens se asoci\u00f3 con Samotics para llevar a cabo una prueba piloto de valor en una de las instalaciones de producci\u00f3n. El objetivo de esta prueba piloto era demostrar la capacidad de las soluciones de monitorizaci\u00f3n continua de activos de Samotics para mejorar el rendimiento y la eficiencia energ\u00e9tica de las bombas cr\u00edticas. Se eligi\u00f3 a Samotics por el rendimiento que ha demostrado en este \u00e1mbito en la industria del agua. Este estudio de caso destaca c\u00f3mo este piloto mejor\u00f3 la eficiencia operativa de una estaci\u00f3n de bombeo de Vitens en m\u00e1s de 7% con la implementaci\u00f3n de simples cambios en el proceso.<\/p>\n<p><a href=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-building.png\"><img decoding=\"async\" class=\"aligncenter wp-image-9671 size-full\" src=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-building.png\" alt=\"\" width=\"888\" height=\"611\" title=\"\" srcset=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-building.png 888w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-building-300x206.png 300w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-building-768x528.png 768w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-building-18x12.png 18w\" sizes=\"(max-width: 888px) 100vw, 888px\" \/><\/a><\/p>\n<h2>Analizar una parte importante de una vasta red h\u00eddrica<\/h2>\n<p>Para poder suministrar continuamente agua potable fiable y asequible, Vitens necesita una amplia infraestructura de agua potable. Se necesitan 117 campos de extracci\u00f3n con 1.250 pozos de extracci\u00f3n de agua subterr\u00e1nea, 100 plantas de tratamiento de agua, 49.000 kil\u00f3metros de tuber\u00edas y 1.400 empleados para suministrar 350 millones de m\u00b3 de agua al a\u00f1o en una amplia zona de los Pa\u00edses Bajos. En el centro de todo ello se encuentran miles de bombas, incluidas bombas de perforaci\u00f3n y bombas de distribuci\u00f3n de agua limpia. En 2021, el consumo de energ\u00eda de la red de Vitens ascendi\u00f3 a 171 GWh. Vitens tiene planes ambiciosos para reducir este nivel de consumo de energ\u00eda como parte de sus objetivos de sostenibilidad para 2030. Se calcula que, en todo el mundo, hasta 40% de la energ\u00eda utilizada por los equipos industriales accionados por motores el\u00e9ctricos se desperdicia debido a ineficiencias operativas, desajustes entre el proceso y la m\u00e1quina y da\u00f1os en desarrollo. Por tanto, existe un amplio margen para mejorar la eficiencia en todas las industrias.<\/p>\n<p>La planta de producci\u00f3n de Vitens en Hoenderloo, en la provincia neerlandesa de Gelderland, fue elegida como ubicaci\u00f3n \u00f3ptima para realizar esta prueba piloto de valor con Samotics. En estas instalaciones, Vitens bombea agua a la superficie mediante un grupo de bombas de sondeo. Una vez tratada, el agua limpia se distribuye a tres lugares a trav\u00e9s de estaciones de bombeo espec\u00edficas.<\/p>\n<h2>Implantaci\u00f3n de una soluci\u00f3n anal\u00edtica avanzada que pueda integrarse con los sistemas de Vitens<\/h2>\n<p>Desde 2010, Vitens trabaja en el programa de innovaci\u00f3n SLIMM, siglas de Self Learning Integrated Model based Management (gesti\u00f3n basada en modelos integrados de autoaprendizaje). El objetivo de este proyecto es digitalizar y automatizar los procesos de gesti\u00f3n de la red de agua, de modo que la calidad del agua potable producida y distribuida pueda controlarse de forma continua y con la mayor eficiencia y eficacia posibles. Un elemento clave del proyecto piloto de Hoenderloo era determinar si la soluci\u00f3n de an\u00e1lisis avanzado Samotics pod\u00eda integrarse con el sistema SLIMM de Vitens. El resultado fue satisfactorio.<\/p>\n<p>Se implant\u00f3 una soluci\u00f3n anal\u00edtica combinada Samotics para la supervisi\u00f3n continua de las 17 bombas de la planta de producci\u00f3n de Hoenderloo (nueve bombas de perforaci\u00f3n y ocho bombas de distribuci\u00f3n de agua limpia). Constaba de: sensores de energ\u00eda, que se instalaron en el interior del armario de control del motor de las bombas para recopilar datos el\u00e9ctricos; una pasarela para el procesamiento inicial de la se\u00f1al...<br \/>\ny distribuci\u00f3n; y acceso a la plataforma anal\u00edtica de referencia de Samotics para transformar estos datos el\u00e9ctricos en recomendaciones de rendimiento\/eficiencia de los activos. Al no ser necesario instalar sensores en ninguna de las bombas, la instalaci\u00f3n se realiz\u00f3 r\u00e1pidamente y se pudo empezar a analizar los datos.<\/p>\n<p><a href=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-sam4-how-it-works.png\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-9675\" src=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-sam4-how-it-works.png\" alt=\"\" width=\"826\" height=\"282\" title=\"\" srcset=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-sam4-how-it-works.png 826w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-sam4-how-it-works-300x102.png 300w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-sam4-how-it-works-768x262.png 768w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-sam4-how-it-works-18x6.png 18w\" sizes=\"(max-width: 826px) 100vw, 826px\" \/><\/a><\/p>\n<p>Un elemento clave de esta soluci\u00f3n total, que abarca espec\u00edficamente la eficiencia energ\u00e9tica, se llama SAM4, cuyos resultados se tratan en este estudio de caso. La soluci\u00f3n se implant\u00f3 para determinar su capacidad de localizar y diagnosticar el derroche de energ\u00eda de las bombas y generar soluciones a estos problemas para ayudar a Vitens a reducir el consumo de energ\u00eda, los costes y las emisiones asociadas de estas bombas. A un nivel m\u00e1s amplio, SAM4 se centra en la eficiencia total de la configuraci\u00f3n del motor de la bomba sobre el terreno, distinguiendo la eficiencia del motor y de la bomba por activo (eficiencia de los componentes), analizando la eficiencia de los activos (configuraci\u00f3n completa de la bomba) y a un nivel superior<br \/>\neficiencia (como las estaciones de bombeo con bombas ubicadas en el mismo lugar).<\/p>\n<p>Mediante la incorporaci\u00f3n de an\u00e1lisis avanzados a su estrategia y sistemas de gesti\u00f3n del agua, Vitens pretend\u00eda determinar en qu\u00e9 casos estas bombas no funcionaban con los modos de funcionamiento m\u00e1s eficientes (lo m\u00e1s cerca posible del punto de m\u00e1xima eficiencia) o podr\u00edan estar sobredimensionadas.<\/p>\n<h2>Localizar las ineficiencias energ\u00e9ticas de las bombas y generar soluciones<\/h2>\n<p>Durante el proyecto piloto, la atenci\u00f3n se centr\u00f3 en tres bombas de distribuci\u00f3n de agua limpia que forman el n\u00facleo de una estaci\u00f3n de bombeo que distribuye agua limpia a Otterlo\/Ede, situada no lejos de la planta de producci\u00f3n de Hoenderloo. Estas bombas son fundamentales para el suministro de agua a los clientes tanto en horas punta como fuera de ellas. Es bastante habitual disponer de varias bombas de distintos tama\u00f1os que trabajan juntas en lugares espec\u00edficos para satisfacer las variaciones de la demanda. Las tres bombas de distribuci\u00f3n de agua limpia incluyen dos bombas de distribuci\u00f3n m\u00e1s grandes de 55 kW (RNP8 y RNP9) y una bomba de distribuci\u00f3n m\u00e1s peque\u00f1a de 11 kW (RNP7). En la siguiente ilustraci\u00f3n se ofrece una visi\u00f3n general de la instalaci\u00f3n.<\/p>\n<p><a href=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-pumping-station-setup.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-9679\" src=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-pumping-station-setup.png\" alt=\"\" width=\"844\" height=\"613\" title=\"\" srcset=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-pumping-station-setup.png 844w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-pumping-station-setup-300x218.png 300w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-pumping-station-setup-768x558.png 768w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-pumping-station-setup-18x12.png 18w\" sizes=\"(max-width: 844px) 100vw, 844px\" \/><\/a><\/p>\n<p>Tras la instalaci\u00f3n de los sensores, la plataforma SAM4 inform\u00f3 a Vitens de que las dos bombas m\u00e1s grandes (RNP8 y RNP9) se utilizaban a menudo de forma ineficiente para suministrar caudales que podr\u00edan cubrirse independientemente de forma mucho m\u00e1s eficiente con la bomba m\u00e1s peque\u00f1a. SAM4 determin\u00f3 adem\u00e1s que una parte significativa de las p\u00e9rdidas de energ\u00eda se deb\u00eda al modo de funcionamiento, que introduc\u00eda p\u00e9rdidas de eficiencia operativa en la bomba y el motor el\u00e9ctrico asociado, lo que supon\u00eda unos 10% de las p\u00e9rdidas totales de eficiencia.<\/p>\n<p><a href=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-sam4-dashboard-pump-curve.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-9681\" src=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-sam4-dashboard-pump-curve.png\" alt=\"\" width=\"644\" height=\"403\" title=\"\" srcset=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-sam4-dashboard-pump-curve.png 644w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-sam4-dashboard-pump-curve-300x188.png 300w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-sam4-dashboard-pump-curve-18x12.png 18w\" sizes=\"(max-width: 644px) 100vw, 644px\" \/><\/a><\/p>\n<p><a href=\"https:\/\/samotics.com\/es\/kb\/sam4-real-time-pump-curve\">Curva de bombeo<\/a> (arriba) que muestra zonas de funcionamiento muy alejadas del punto de mejor rendimiento de la bomba RNP8 en febrero de 2022 (RNP9 mostr\u00f3 un funcionamiento ineficiente similar). En las m\u00e9tricas (abajo) generadas por SAM4 Energy se observa que el rendimiento de estas dos bombas de 55 kW se sit\u00faa en torno a 69%, por debajo de lo que se considera un funcionamiento eficiente.<\/p>\n<p><a href=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-sam4-dashboard-energy-savings.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-9683\" src=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-sam4-dashboard-energy-savings.png\" alt=\"\" width=\"722\" height=\"414\" title=\"\" srcset=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-sam4-dashboard-energy-savings.png 722w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-sam4-dashboard-energy-savings-300x172.png 300w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-sam4-dashboard-energy-savings-18x10.png 18w\" sizes=\"(max-width: 722px) 100vw, 722px\" \/><\/a><\/p>\n<p>Las p\u00e9rdidas de funcionamiento de las bombas RNP8 y RNP9 suponen unas 10% de p\u00e9rdidas totales de rendimiento. Estas p\u00e9rdidas pueden reducirse mejorando el funcionamiento de las bombas.<\/p>\n<h2>Puesta en pr\u00e1ctica de los consejos generados y seguimiento de las mejoras de las bombas<\/h2>\n<p>Vitens aplic\u00f3 dos sencillos cambios de configuraci\u00f3n aconsejados por la plataforma SAM4 para lograr un bombeo m\u00e1s eficiente durante los periodos de bajo caudal. En la primera fase de estas actividades, se ajust\u00f3 el umbral de caudal de cambio: se aument\u00f3 el umbral de caudal al que la bomba de 11 kW suministraba caudal, ya que la bomba de 11 kW pod\u00eda suministrar el caudal bajo de forma independiente y m\u00e1s eficiente que dos bombas de 55 kW. A continuaci\u00f3n, se realiz\u00f3 un seguimiento del caudal, el consumo energ\u00e9tico y la eficiencia resultantes mediante la plataforma SAM4.<\/p>\n<p>La segunda fase de este cambio operativo aument\u00f3 la velocidad de la bomba de 11 kW con el fin de ampliar a\u00fan m\u00e1s el rango de funcionamiento \u00fatil de la bomba m\u00e1s peque\u00f1a para suministrar un mayor caudal a la presi\u00f3n requerida. Para ello se aument\u00f3 la frecuencia de alimentaci\u00f3n del variador de frecuencia, sin sobrepasar la potencia nominal del motor ni la capacidad de la bomba. El resultado fue un mayor rango de caudal factible para la bomba de 11 kW, encendiendo las bombas m\u00e1s grandes s\u00f3lo cuando era realmente necesario.<\/p>\n<p><a href=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-energy-savings-graph.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-9684\" src=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-energy-savings-graph.png\" alt=\"\" width=\"864\" height=\"243\" title=\"\" srcset=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-energy-savings-graph.png 864w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-energy-savings-graph-300x84.png 300w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-energy-savings-graph-768x216.png 768w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-energy-savings-graph-18x5.png 18w\" sizes=\"(max-width: 864px) 100vw, 864px\" \/><\/a><\/p>\n<p>Los dos sencillos cambios de proceso aplicados tuvieron un efecto significativo en el rendimiento de las tres bombas de una de las estaciones de bombeo de la planta de producci\u00f3n de Hoenderloo. Teniendo en cuenta la distribuci\u00f3n del tiempo de funcionamiento, la presi\u00f3n y el caudal en las situaciones antigua y nueva, el rendimiento el\u00e9ctrico global de la estaci\u00f3n de bombeo aument\u00f3 en 7,1%.<\/p>\n<p><a href=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-sam4-dashboard-pump-curve-2.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-9686\" src=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-sam4-dashboard-pump-curve-2.png\" alt=\"\" width=\"631\" height=\"396\" title=\"\" srcset=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-sam4-dashboard-pump-curve-2.png 631w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-sam4-dashboard-pump-curve-2-300x188.png 300w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-sam4-dashboard-pump-curve-2-18x12.png 18w\" sizes=\"(max-width: 631px) 100vw, 631px\" \/><\/a><\/p>\n<p>Tras la aplicaci\u00f3n de los dos cambios de proceso, cada bomba funcionaba en mayor medida en condiciones de funcionamiento m\u00e1s eficientes (zonas verdes) y menos en condiciones m\u00e1s ineficientes (zonas rojas). Esta es la situaci\u00f3n de una de las bombas m\u00e1s grandes de 55 kW antes (izquierda) y despu\u00e9s (derecha) de aplicar los cambios en el proceso.<\/p>\n<h2>Validaci\u00f3n de resultados<\/h2>\n<p>Una vez aplicados estos sencillos cambios en el proceso, la mejora de la situaci\u00f3n pudo apreciarse inmediatamente a trav\u00e9s de la plataforma SAM4 en el monitor de energ\u00eda y la curva de la bomba generada. Los cambios operativos, relativamente sencillos, se pudieron realizar sin inversiones adicionales y consiguieron que las tres bombas funcionaran m\u00e1s cerca de sus puntos de m\u00e1xima eficiencia. Esto aument\u00f3 el rendimiento y la fiabilidad de las bombas. El rendimiento total de la estaci\u00f3n de bombeo mejor\u00f3 en 7,1%, teniendo en cuenta la distribuci\u00f3n del tiempo de funcionamiento, la presi\u00f3n y el caudal en las situaciones antigua y nueva.<\/p>\n<p>Esto se traduce en un ahorro anual de electricidad de 2.500 euros en las tres bombas y una reducci\u00f3n asociada de 9,2 toneladas de CO2 basada \u00fanicamente en la reducci\u00f3n de energ\u00eda. Otro aspecto importante es que un funcionamiento ineficiente puede duplicar las posibilidades de aver\u00eda y acortar la vida \u00fatil de los equipos industriales. Por tanto, la mejora de la salud operativa puede suponer un ahorro adicional.<\/p>\n<p><a href=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-vitens-yearly-savings.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-9687\" src=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-vitens-yearly-savings.png\" alt=\"\" width=\"1040\" height=\"461\" title=\"\" srcset=\"https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-vitens-yearly-savings.png 1040w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-vitens-yearly-savings-300x133.png 300w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-vitens-yearly-savings-1024x454.png 1024w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-vitens-yearly-savings-768x340.png 768w, https:\/\/samotics.com\/wp-content\/uploads\/2024\/09\/vitens-success-story-vitens-yearly-savings-18x8.png 18w\" sizes=\"(max-width: 1040px) 100vw, 1040px\" \/><\/a><\/p>\n<blockquote><p>Estamos viendo que en Vitens la mayor parte de la energ\u00eda la consumen las bombas para distribuir agua limpia a nuestros clientes. En este proyecto piloto SAM4 hemos visto r\u00e1pidamente que hay mucho que ganar mejorando la eficiencia operativa de las bombas y reduciendo as\u00ed su consumo de energ\u00eda sin dejar de satisfacer la demanda.<\/p>\n<p><strong>Rein Wuestman<\/strong>Ingeniero de procesos, Vitens<\/p><\/blockquote>\n<h2>Buenas perspectivas para el abastecimiento sostenible de agua<\/h2>\n<p>Con el fin de suministrar agua a sus clientes de forma m\u00e1s sostenible, Vitens busca medios m\u00e1s innovadores para hacer frente a los retos que se le plantean de aqu\u00ed a 2030 y m\u00e1s all\u00e1. Con el aumento de los costes y la volatilidad del mercado energ\u00e9tico, cada vez es m\u00e1s importante reducir el consumo de energ\u00eda, tanto desde el punto de vista de los costes como de la sostenibilidad.<\/p>\n<p>En el caso de Vitens, la colaboraci\u00f3n con Samotics ha demostrado que el uso de an\u00e1lisis avanzados de datos energ\u00e9ticos en una de sus estaciones de bombeo ha garantizado un ahorro anual recurrente en el consumo de energ\u00eda, los costes y la reducci\u00f3n de las emisiones asociadas. El m\u00e9todo utilizado para conseguir ahorros energ\u00e9ticos en esta evaluaci\u00f3n es tambi\u00e9n muy aplicable a otras bombas de la red de Vitens.<\/p>\n<p>La realizaci\u00f3n de este piloto de prueba de valor SAM4 ha resultado una experiencia positiva para Vitens y Samotics. Ha demostrado c\u00f3mo se puede mejorar significativamente la eficiencia el\u00e9ctrica, y en poco tiempo, localizando las ineficiencias energ\u00e9ticas en las bombas industriales, generando soluciones concretas a estas ineficiencias e implantando cambios sencillos en los procesos que no suponen ninguna inversi\u00f3n adicional.<\/p>\n<p>Tambi\u00e9n demostr\u00f3 que la implantaci\u00f3n de un sistema de este tipo puede realizarse con rapidez y ser capaz de integrarse con los sistemas propios de Vitens. Para Vitens, esto significa que el avance hacia un ecosistema h\u00eddrico m\u00e1s sostenible est\u00e1 mucho m\u00e1s cerca.<\/p>","protected":false},"excerpt":{"rendered":"<p>Vitens\u2019 ambitious strategy to improve sustainability with industrial efficiency \u201cEvery Drop Sustainable,\u201d that\u2019s the vision at the heart of Vitens, the largest drinking water company in The Netherlands. The utility delivers high-quality drinking water to 5.6 million people and companies in 7 of the 12 Dutch provinces. Vitens understands that reliable drinking water is a [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":9760,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"content-type":"","_lmt_disableupdate":"no","_lmt_disable":"","footnotes":""},"categories":[6],"tags":[],"coauthors":[63],"class_list":["post-9663","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-case-studies"],"modified_by":"Gino Gagliardi","_links":{"self":[{"href":"https:\/\/samotics.com\/es\/wp-json\/wp\/v2\/posts\/9663","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/samotics.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/samotics.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/samotics.com\/es\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/samotics.com\/es\/wp-json\/wp\/v2\/comments?post=9663"}],"version-history":[{"count":5,"href":"https:\/\/samotics.com\/es\/wp-json\/wp\/v2\/posts\/9663\/revisions"}],"predecessor-version":[{"id":9765,"href":"https:\/\/samotics.com\/es\/wp-json\/wp\/v2\/posts\/9663\/revisions\/9765"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/samotics.com\/es\/wp-json\/wp\/v2\/media\/9760"}],"wp:attachment":[{"href":"https:\/\/samotics.com\/es\/wp-json\/wp\/v2\/media?parent=9663"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/samotics.com\/es\/wp-json\/wp\/v2\/categories?post=9663"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/samotics.com\/es\/wp-json\/wp\/v2\/tags?post=9663"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/samotics.com\/es\/wp-json\/wp\/v2\/coauthors?post=9663"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}